KX补偿导线_ZR-KX-HA-FVP阻燃补偿导线
添加时间: | 2022-03-12 23:11:27 |
---|---|
推荐度: |
全称:氟塑料烯J缘PVC护套铜丝编织总屏蔽准确K分度号热电偶用阻燃型补偿电缆
ZR-KX-HA-FVP阻燃补偿导线
耐高温200℃补偿导线ZR-KX-HA-FGP氟塑料J缘硅橡胶护套铜丝编织屏蔽准确K分度号热电偶补偿导线
基本型号及M称KX-FF46-RP1 KX-HA-FFRP KX-GA-VV KX-HA-FGR
1:热电偶用补偿导线
KX-GA-VV | PVCJ缘PVC护套准确K分度号热电偶补偿导线 |
KX-GA-VVR | PVCJ缘PVC护套准确K分度号热电偶补偿软导线 |
KX-GA-VVP | PVCJ缘PVC护套铜丝编织屏蔽准确K分度号热电偶补偿导线 |
KX-GA-VVRP | PVCJ缘PVC护套铜丝编织屏蔽准确K分度号热电偶补偿软导线 |
KX-HA-FF | 氟塑料J缘和护套准确K分度号热电偶补偿导线 |
KX-HA-FFR | 氟塑料J缘和护套准确K分度号热电偶补偿软导线 |
KX-HA-FFP | 氟塑料J缘和护套铜丝编织屏蔽准确K分度号热电偶补偿导线 |
KX-HA-FFRP | 氟塑料J缘和护套铜丝编织屏蔽准确K分度号热电偶补偿软导线 |
KX-HA-FG | 氟塑料J缘硅橡胶护套准确K分度号热电偶补偿导线 |
KX-HA-FGR | 氟塑料J缘硅橡胶护套准确K分度号热电偶补偿软导线 |
KX-HA-FGP | 氟塑料J缘硅橡胶护套铜丝编织屏蔽准确K分度号热电偶补偿导线 |
KX-HA-FGRP | 氟塑料J缘硅橡胶护套铜丝编织屏蔽准确K分度号热电偶补偿软导线 |
KX-HA-FV | 氟塑料J缘PVC护套准确K分度号热电偶补偿导线 |
KX-HA-FVR | 氟塑料J缘PVC护套准确K分度号热电偶补偿软导线 |
KX-HA-FVP | 氟塑料J缘PVC护套铜丝编织屏蔽准确K分度号热电偶补偿导线 |
KX-HA-FVRP | 氟塑料J缘PVC护套铜丝编织屏蔽准确K分度号热电偶补偿软导线 |
KX-GA-YJV | 交联聚乙烯J缘PVC护套准确K分度号热电偶补偿导线 |
KX-GA-YJVR | 交联聚乙烯J缘PVC护套准确K分度号热电偶补偿软导线 |
KX-GA-YJVP | 交联聚乙烯J缘PVC护套铜丝编织屏蔽准确K分度号热电偶补偿导线 |
KX-GA-YJVRP | 低烟无卤J缘和护套铜丝编织屏蔽准确K分度号热电偶补偿软导线 |
KX-GA-YDYD | 低烟无卤J缘和护套准确K分度号热电偶补偿导线 |
KX-GA- YDYD R | 低烟无卤J缘和护套准确K分度号热电偶补偿软导线 |
KX-GA- YDYD P | 低烟无卤J缘和护套铜丝编织屏蔽准确K分度号热电偶补偿导线 |
KX-GA- YDYD RP | 低烟无卤J缘和护套铜丝编织屏蔽准确K分度号热电偶补偿软导线 |
注:上述型号仅列出KX,其他如SC、KC、EX、BC、TX、JX只需改变型号项即可, 阻燃型补偿导线型号前加ZR,ZR192为PFA材料, 屏蔽可采用镀锡铜丝屏蔽。 |
KX-HA-FVP补偿电缆详细参数
导体材质: 正为镍铬----负为镍硅 准确热电偶补偿电缆 分度号K型 |
J缘材料:高温氟塑料J缘 颜色:正为红色 负为黑色 J缘温度:-20-180℃ |
护套材料 阻燃PVC护套 颜色:灰色 温度:-20-105 |
可根据需要提供聚乙烯(Y)J缘、 交联聚乙烯(YJ)J缘补偿电缆。 |
屏蔽材质:铜丝屏蔽或镀锡屏蔽 |
J缘电阻: 25MΩ.km |
电压试验:1000 V/1min |
阻燃性能:符合GB/T18380-2001阻燃标准中A、 B、 C类规定 |
热电动势及允差:准确 8137 ±60(±1.5℃) |
KX-HA-FVP补偿电缆规格
导线规格 | A类导体 | R类导体 | 20℃时往复电阻≤Ω/m |
2×0.5 mm² | 1/0.80 | 7/0.30 | 2.2 |
2×1.0 mm² | 1/1.13 | 7/0.43 | 1.1 |
2×1.5 mm² | 1/1.37 | 7/0.52 | 0.73 |
2×2.5 mm² | 1/1.76 | 19/0.41 | 0.44 |
电缆规格 | |||
1×2×0.5 | 7×2×2.5 | 2×2×1.0 | 5×2×1.0 |
1×2×1.0 | 8×2×0.5 | 2×2×1.5 | 5×2×1.5 |
1×2×1.5 | 8×2×1.0 | 2×2×2.5 | 10×2×1.5 |
1×2×2.5 | 8×2×1.5 | 3×2×0.5 | 10×2×2.5 |
5×2×2.5 | 8×2×2.5 | 3×2×1.0 | 12×2×0.5 |
6×2×0.5 | 9×2×0.5 | 3×2×1.5 | 12×2×1.0 |
6×2×1.0 | 9×2×1.0 | 3×2×2.5 | 12×2×1.5 |
6×2×1.5 | 9×2×1.5 | 4×2×0.5 | 12×2×2.5 |
6×2×2.5 | 9×2×2.5 | 4×2×1.0 | 14×2×0.5 |
7×2×0.5 | 10×2×0.5 | 4×2×1.5 | 14×2×1.0 |
7×2×1.0 | 10×2×1.0 | 4×2×2.5 | 14×2×1.5 |
7×2×1.5 | 2×2×0.5 | 5×2×0.5 | 14×2×2.5 |
16×2×1.5 | 19×2×0.5 | 19×2×1.5 | 16×2×0.5 |
16×2×2.5 | 19×2×1.0 | 19×2×2.5 | 16×2×1.0 |
使用特性
1. 低环境温度:PVC护套:固定敷设-40℃,非固定敷设-15℃
氟塑料J缘和护套:固定敷设-60℃,非固定敷设-20℃
2. 导体高工作温度:耐热:聚全氟乙丙烯(F46)200℃
可溶性聚四氟乙烯260℃,硅橡胶180℃
普通:PVC70℃和105℃,交联聚乙烯90℃
低烟无卤阻燃聚烯烃70℃,交联型90℃和125℃
3. 电缆允许弯曲半径: 非铠装电缆小为外径的6倍
铜带屏蔽或钢带铠装点缆小为电缆外径的12倍
氟塑料J缘和护套小为电缆外径的10倍