屏蔽控制电缆KYJVP、KVVP2
添加时间: | 2022-08-09 07:53:55 |
---|---|
推荐度: |
屏蔽控制电缆KYJVP、KVVP2 | 工序名称 | 外护套挤塑工序(Ф65挤塑机或Ф90挤塑机) | 编 号 | AICS/QESZ--43 | ||
产品名称 | 聚氯乙烯绝缘和护套控制电缆 | 代 替 | ||||
执行标准 | GB/9330-2008 | 型 号 | KVV、KYJV.、KVVP、KYJVP、KVVP2、KYJVP2KVVR、KVV22、KVVRP | 规格 | 2-61mm2 | |
续表1 KVV型电缆外护套挤塑工艺参数 芯数×标称截面mm2导体种类护套前线芯外径mm护套标称厚度mm模芯尺寸mm模套尺寸mm护套外径mm10×4115.91.718.027.019.310×4217.21.719.528.020.610×6117.91.720.029.021.310×6219.71.721.531.023.110×10224.71.726.536.028.112×0.7519.31.511.520.012.312×0.75210.01.512.021.013.012×1.019.91.512.021.012.912×1.0210.61.512.521.513.612×1.5111.81.514.023.014.812×1.5212.71.514.523.515.712×2.5114.31.516.525.017.312×2.5215.41.517.526.018.412×4116.31.718.527.519.712×4217.51.719.529.020.912×6118.41.720.520.021.812×6220.11.722.531.523.514×0.7519.91.512.021.012.914×0.75210.61.512.521.513.614×1.0110.51.512.521.513.514×1.0211.31.513.522.514.314×1.5112.51.514.523.015.514×1.5213.51.515.524.016.514×2.5115.21.517.526.018.214×2.5216.41.518.527.519.414×4117.21.719.528.520.614×4218.61.720.529.022.014×6119.61.721.531.023.314×6221.31.723.533.024.7 |
上一篇:KYJV、KVVP控制电缆参数
下一篇:KYJVP2控制电缆KVVR
浏览: